PerkinElmer DSC 4000 Comprehensive Solutions for Differential Scanning Calorimetry (520A006095)

The PerkinElmer DSC 4000 is a state-of-the-art differential scanning calorimeter, designed to deliver accurate, high-performance thermal analysis for a broad range of industries, including pharmaceuticals, materials science, polymers, and food processing. This system offers comprehensive solutions for investigating thermal properties, phase transitions, crystallization, and much more.

Technical Specifications:

  • Temperature Range: -90°C to 600°C
  • Heat Flow Sensitivity: High sensitivity for precise heat flow measurements
  • Heating/Cooling Rate: Adjustable from 0.01°C/min to 100°C/min
  • Sample Capabilities: Accommodates both solid and liquid samples
  • High-Pressure Capability (Optional): Optional high-pressure module for elevated pressure studies
  • Software: Integrated with Pyris Software for data acquisition, analysis, and reporting
  • Auto Calibration: Automatic calibration routines for consistent, reliable results
  • Calorimetric Performance:

    • Dynamic range: ±175 mW
    • Accuracy: ±2%
    • Precision: ±0.1%
    • Indium height/width (mW/°C): 8
    • Indium melting time (sec): 3.3
    • Digital resolution: 0.02 μW

  • Temperature Performance:

    • Range: -100°C to 450°C
    • Accuracy: ±0.1°C
    • Precision: ±0.02°C
    • Data points/sec: 10
    • Controlled heating rates: 0.1 to 100°C/min
    • Controlled cooling rates: 0.1 to 100°C/min
    • Cooling times (100°C to 0°C): Under 4 minutes

  • Dimensions: 17 x 38 x 41 cm (6.7” x 15” x 16.5”)
  • Weight: 16.5 kg (36 lb), 19 kg with Autosampler (42 lb)
  • Power Requirements: 100-240 Volt 50/60 Hz

Features:

  • Integrated Mass Flow Controller: For convenient gas control and switching
  • Autosampler Option: Fast 45-position autosampler for reliable unattended operation
  • Cooling Accessories: Chiller, circulator, intracooler, portable cooling device, Cryofill (liquid N2)
  • Regulatory Compliance: 21 CFR Part 11 compliance (optional)

The DSC 4000 is designed to provide dependable performance and quality results for a wide range of routine applications in various industries.

Maintenance Requirements:
Ensure the unit is clean maintenance to be carried out if a drift is observed in the calibrating of the machine

Calibration Requirements:
Calibrate prior to test run using reference samples,
Record Calibration Results in the Indium Control Results

Related Products

What Our Clients Say

Supporting innovation at leading research companies

RNAnalytics

RNAnalytics

Leading The Way In Gene Therapy Analytics

As a startup focused on developing analytical toolkits for LNP characterization, RNAnalytics operates under tight budget constraints while striving to maintain a fully stocked lab with high-quality materials. Sustainability is also a core pillar of our operations, pushing us to make environmentally conscious decisions wherever possible....